Sale!
SR-508 Yokogawa Safety Relay Module
$ 95.56
Ready to Ship
Description SR-508 Yokogawa Safety Relay Module Product Dimensions: Product Description (Detailed Explanation) The SR-508-00 acts as a safety barrier between control logic (such as a PLC or Safety System) and field-mounted final control elements. Its primary function is to ensure a safe shutdown in the event of an emergency or system failure. For example, it is frequently used to cut off the fuel supply to industrial incinerators or power down hazardous machinery. The module features safe isolation between the input (coil side) and the output (contact side), meeting strict overvoltage standards. It is built using a diverse relay architecture to prevent systematic failures and is certified for use in high-integrity safety loops (up to SIL4 in specific configurations). Product Parameters (Technical Specifications) Parameter Category Specification Number of Channels 1 Channel Input Voltage 24V DC (-15% to 20%) Input Current 35 mA – 40 mA Output Contact Type Normally Open (NO) Contact Material Gold-plated over silver alloy Maximum Load (AC) 250V AC, 2A ($\cos \phi > 0.5$) Maximum Load (DC) 30V DC / 2A; 127V DC / 0.2A Isolation Strength 4 kVrms (1 min); 6 kV Surge Response Time On: 3–10 ms / Off: 5–7 ms Mechanical Life 30 million operations Mounting 35mm DIN Rail (IP20 Protection) Product Advantages (Key Benefits) Extreme Safety Standards: Designed to meet SIL4 requirements, providing the highest level of risk reduction for industrial processes. Robust Isolation: Excellent galvanic isolation (4 kV) ensures that high-voltage surges on the output side do not damage the sensitive low-voltage control electronics. Diagnostic Visibility: Equipped with a bright Red LED indicator on the front panel, allowing maintenance personnel to verify the relay status at a glance. Field-Proven Reliability: Built with high-quality components and gold-plated contacts to ensure reliable switching even after long periods of inactivity (preventing contact oxidation). Compact Design: The slim, DIN-rail mountable housing saves significant space in high-density control cabinets. Precautions (Important Notes) Terminal Usage: Terminals 5 and 8 are designated as test terminals and must not be used during normal operational mode. Cyclic Testing: To maintain its safety integrity (SIL rating), the module must be tested upon every system power-up and undergo a full functional check every two years. Replacement Policy: Internal components are not user-serviceable. Any repair or component replacement must be performed by the manufacturer to comply with TÜV safety restrictions. Environmental Limits: While rugged, the unit should be installed in an IP54 or higher enclosure if used in environments with conductive dust or high moisture. Product Applications (Typical Use Cases) Emergency Shutdown Systems (ESD): Integrated into the safety logic of oil and gas platforms to trigger immediate process isolation. Burner Management Systems (BMS): Controlling the main fuel shut-off valves for industrial boilers and incinerators to prevent explosions. Fire & Gas Systems: Interfacing between fire detectors and suppression equipment (like foam deluges or CO2 systems). High-Pressure Interlocks: Used in chemical reactors to vent pressure or stop pumps when critical safety thresholds are exceeded. Machinery Guarding: Providing a safe interface for light curtains and E-stop circuits in high-speed manufacturing lines. Please make an inquiry for more models: YOKOGAWA F3SV64 YOKOGAWA FAW05-5RO YOKOGAWA PW302-S4 YOKOGAWA PW401-S2 YOKOGAWA PW441-10 YOKOGAWA PW441-50 YOKOGAWA PW442-10 YOKOGAWA PW481-01 YOKOGAWA PW481-10 YOKOGAWA PW481-11 YOKOGAWA PW481-50 YOKOGAWA PW482-11 YOKOGAWA PW484-10 YOKOGAWA CP451 YOKOGAWA LR4220E YOKOGAWA ST6A YOKOGAWA MS31*A YOKOGAWA MX6*A YOKOGAWA NC4*B YOKOGAWA PS31*A YOKOGAWA MAC2*B YOKOGAWA FCA4*B YOKOGAWA VM1*D YOKOGAWA LC82*A YOKOGAWA 2150S YOKOGAWA ST6*A YOKOGAWA C2L315601-1111 YOKOGAWA DM1A-050G YOKOGAWA MW100-E-1R YOKOGAWA AV8C-A-4-EA/4P








